High-Precision Digital Flow Meter for Oil & Gas Applications
Contact Supplier
Product Highlights
- Wide Flow Range Ratio: Ratio up to 1000:1, with configurable flow velocity from 0.5m/s to 10m/s.
- No Moving Parts Design: Zero obstruction in measuring tube, ensuring no pressure loss and minimal maintenance.
- Corrosive Media Resistance: Compatible with acids, alkalis, and salt solutions using PTFE, PFA, or Hastelloy materials.
- Bidirectional Flow Measurement: Supports forward, reverse, and net total flow measurement with three built-in totalizers.
- Flexible Output Options: Offers 4-20mA, Pulse, RS485, HART, and Profibus-PA communication protocols.
- IP68 Protection Grade: Available in IP65, IP67, and IP68 ratings for submerged or harsh environment installation.
- Customizable Pressure Rating: Pressure ratings up to 42 MPa available, with customized options for specific needs.
Product Attributes
- Customization
- Available
- After-sales Service
- on Line
- Warranty
- 12 Months
- Model NO.
- AEMF
- Accuracy
- 0.1-1.0%
- Main Application
- Water, Wastewater, Diesel Fuel, Corrosive Liquid/Gas
- Size
- DN10 ~ DN2000
- Sensor
- Threaded
- Application
- Industrial Production
- Type
- Electromagnetic Flow Meter
- Measuring Media
- Liquid
- Measuring Principle
- Electrical Principles
- Measurement Object
- Closed Pipeline
- Certification
- JIS, DIN, ANS, CE, ISO, ATEX, Iece, Sil, CE
- Medium
- Conductive Liquids
- Nominal Diameter
- DN10 ~ DN2000
- Conductivity Requirement
- ≥5 μS/Cm
- Pressure Rating
- Pn10 / Pn16 / Pn25 / Customized
- Output Signal
- 4-20mA / Pulse / RS485 / Hart
- Power Supply
- 24VDC / 220VAC
- Lining Material
- PTFE / Rubber / PFA
- Electrode Material
- SS316L / Hastelloy / Titanium / Tantalum
- Protection Grade
- IP65 / IP67 / IP68
- Communication
- Modbus RTU / Hart
- Transport Package
- Carton
- Trademark
- ANDISOON
- Origin
- Sichuan, China
- HS Code
- 90261000
- Production Capacity
- 2000 Pices/Year
- Package Size
- 35.00cm * 45.00cm * 60.00cm
Shipping
- Shipping Cost:
- Contact the supplier about freight and estimated delivery time.
Online Trading Protection
- Payment Guarantee
-
Platform-protected payments with refund support for eligible order issues.
- Platform Logistics
- Clearer shipment tracking with platform-supported logistics.
- Inspection Service
- Optional pre-shipment inspection for quality and quantity checks.
- After-Sales & Dispute Handling
- Platform-assisted dispute resolution, including refunds or returns when applicable.
Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.
Product Images of High-Precision Digital Flow Meter for Oil & Gas Applications
Find Similar Products
Product Description
AEMF Series Electromagnetic Flowmeter
Chengdu Andisoon Measure Co., Lt
An electromagnetic flow meter is an instrument that measures liquid flow based on Faraday's law of electromagnetic induction. It is capable of measuring the flow of various conductive liquids, such as water, wastewater, and chemical fluids.
Electromagnetic flow meters offer high accuracy, excellent stability, no moving parts, and strong resistance to media corrosion. Because of these advantages, they are widely used in industries such as water treatment, wastewater management, chemical processing, food and beverage, and pharmaceuticals for flow measurement and process control.
The working principle of an electromagnetic flow meter is based on generating a magnetic field when conductive liquid flows through a pipe. The induced voltage produced by the fluid passing through the magnetic field is proportional to the flow velocity, allowing accurate flow measurement.
Electromagnetic flow meters are available in multiple models and specifications. The appropriate type can be selected based on the properties of the liquid, flow range, and operating environment.
In summary, the electromagnetic flow meter is a high-precision, stable, and maintenance-free flow measurement instrument that is widely used for accurate measurement and control of conductive liquid flow across a broad range of industrial applications.
High accuracy: 0.15%.The measured volumetricflow rate is not affected by fluid density,viscosity,temperature orpressure.
Noclogdesign: Lower pressureloss.
Bidirectional Flow Measurement: Capable of measuringflowin
Best choice for corrosive process fluids: Various electrodes and linings,suitable fo all typesof conductive corrosive liquids such as acids,alkalis,and salt solutions.
Wide range ratio: 20:1 to 1000:1,with selectable wide flow ranges.The full-scale liquid flow velocity can be configured between 0.5m/s and
10m/s.
Easy installation: Lower requirements forstraight pipe line,5Dupstream straight pipe,2D downstream straight pipe.
Wideline size: DN 3mm to DN 3000mm.
·Measurement accuracy is not affected by changes in fluid density, viscosity, temperature, pressure, or electrical conductivity, ensuring stable performance in various applications
·The measuring tube has no obstructing moving parts and causes no pressure loss, helping reduce energy consumption.
·Low requirements for straight pipe sections, saving installation space.
·The converter uses an LCD backlit display, ensuring easy reading in both direct sunlight and dark environments.
·Parameters can be configured via infrared touch buttons, allowing safe operation without opening the converter cover even in harsh environments.
·The flow meter supports bidirectional measurement and includes three built-in totalizers: forward total, reverse total, and net total, with display of both forward and reverse flow.
·Multiple output options are available, including current output, frequency/pulse output, HART communication, and RS485 digital communication.
·Equipped with self-diagnostic alarm functions, empty pipe detection, and high/low flow alarm outputs.
·Suitable not only for general process monitoring but also for measuring slurries, pulp, and viscous fluids.
The measurement principle is based on Faraday's law of electromagnetic induction. When a conductor moves through a magnetic field and cuts magnetic flux lines, an electromotive force is generated in the conductor. The induced electromotive force E is expressed as:
E = K B V D
K: Instrument constant
B: Magnetic flux density
V: Average flow velocity across the cross-section of the measuring tube
D: Inner diameter of the measuring tube
| Nominal Diameter | DN3~DN3000 |
| Pressure limited | Maximum 42 MPa |
| Accuracy | ±0.5% of reading(±0.2%,±0.3%Optional) |
| Liner Materials | PTFE,PFA,F46,chloroprene rubber,silicone fluorine rubber,polyurethane rubber |
| Electrode Type | Standard type,scraper type |
| Electrode Materials | 316L,Hastelloy C,Hastelloy B,Titanium,Tantalum,Platinum-Iridium alloy,316L |
| coated with tungsten carbide | |
| Medium Temperature | -40ºC~180ºC |
| -40°ºC~180ºC(Related to liner) | |
| Ambient Temperature | -40ºC~60ºC |
| Ambient Humidity | 5%-95%non-condensing |
| Conductivity | ≥20μs/cm |
| Flow Range | 1000:1(flow rate <15m/s) |
| Structure | integral type,remote type,immersion type,explosion-proof type |
| Conduit | M20*1,5F,1/2NPTF |
| Enclosure | IP65,IP66,IP67,IP68 IP65,IP66,IP67,IP68 optional |
| Installation Type | flange type,wafer type,insert type |
| Output Signal | pulse+4~20mA+HART,Pulse+4~20mA+RS485,Profibus-PA |
| Power Supply | 220VAC/50Hz,24VDC,3.6V Lithium battery |
| Explosion-Proof | Exdb ia[iaGa]qII CT6Gb |
| certification | |
| Product Standard | JB/T2948-2015 |
Converter Performance Parameters
| Power Supply | AC 220V 50Hz / DC 24V / 3.6V battery powered | |||
| Power Consumption | Power Consumption | |||
| Power Consumption | Bilingual (Chinese/English) display; shows instantaneous flow, total flow, and alarm status (excitation circuit failure alarm, empty pipe alarm, flow limit alarm); equipped with four membrane touch keys for parameter setting | |||
| Totalizer | Forward total, reverse total, net (difference) total | |||
Output Signals |
|
4~20mADC;Load Resistance:0~750Ω | ||
Frequency/Pulse Output |
Used for forward or reverse instantaneous flow measurement; range: 1-5000 Hz or up to 5000 pulses/s; electrical isolation via optocoupler, isolation voltage >1000 VDC; output driver: MOSFET output, max voltage 35 VDC, max load current 250 mA | |||
| range: 1-5000 Hz or up to 5000 pulses/s; output driver: | ||||
| electrical isolation via optocoupler, isolation voltage >1000 VDC; | ||||
| MOSFET output, max voltage 35 VDC, max load current 250 mA | ||||
Alarm Output(Optional) |
Used for high/low flow limit alarms; output driver: | |||
| electrical isolation via optocoupler, isolation voltage >1000 VDC; | ||||
| MOSFET output, max voltage 35 VDC, max load current 250 mA | ||||
| Communication | Optional RS485 / HART communication | |||
| Accuracy | Optional RS485 / HART communication | |||
| Damping Time | Adjustable from 0-100 s (90% response time, segmented settings available) | |||
| Lightning Protection | Yes | |||
| Lightning Protection | Built-in non-volatile clock; stores up to 16 power-off records (10-year retention) | |||
| Protection Class | IP65 | |||
| Explosion-proof Marking | Ex db ia [ia Ga] q IIC T6 Gb | |||
| Parameter | Specification |
| Nominal Diameter | DN3 mm - DN900 mm |
| Nominal Pressure | 0.6 - 4.0 MPa (custom higher pressure available) |
| Accuracy | ±0.5% of reading; optional ±0.3% or ±0.2% of reading |
| Liner Materials | Chloroprene rubber, polyurethane rubber, fluorosilicone rubber, PTFE, FEP (F46), PFA |
| Electrode Types | Standard type, scraper type, replaceable type (customizable) |
| Electrode Materials | SS316L, Hastelloy B, Hastelloy C, titanium, tantalum, Monel, platinum/iridium alloy, stainless steel coated with tungsten carbide |
| Item | Specification |
| Nominal Diameter | DN25 mm ~ DN250 mm |
| Nominal Pressure | 6.3 MPa, 10 MPa, 16 MPa, 25 MPa, 42 MPa |
| Accuracy | ±0.5% of reading, optional ±0.3% or ±0.2% of reading |
| Liner Materials | PTFE (Polytetrafluoroethylene), FEP (F46), PFA |
| Electrode Materials | SUS316, Hastelloy B, Hastelloy C, Titanium, Stainless Steel with Tungsten Carbide Coating |
| Structure Type | Integral type, split type |
| Medium Temperature (FEP / PFA Lining) | -10°C ~ +160°C |
| Medium Temperature (PTFE Lining) | -10°C ~ +120°C |
| Ambient Temperature | -25°C ~ +60°C |
| Medium Conductivity | ≥20 μS/cm |
| Connection Type | Flange type, Hammer Union type |
| Product Standard | JB/T9248-2015 Electromagnetic Flowmeter |
| Electrode Material | Corrosion Resistance Characteristics |
| SUS316 | Suitable for industrial water, potable water, wastewater, and mildly corrosive media. Widely used in petroleum, chemical, steel industries, as well as municipal and environmental protection applications. |
| Hastelloy B (HB) | Resistant to non-oxidizing acids such as hydrochloric acid, sulfuric acid, phosphoric acid, hydrofluoric acid, organic acids, as well as alkalis and non-oxidizing salt solutions at room temperature. |
| Hastelloy C (HC) | Resistant to oxidizing salts such as Fe and Cu salts or media containing other oxidizing agents. Also resistant to hypochlorite solutions and seawater corrosion. |
| Titanium (Ti) | Resistant to seawater, various chlorides and hypochlorites, oxidizing acids (including fuming sulfuric acid), organic acids, and alkalis. However, corrosion resistance decreases significantly in acids containing oxidizing agents such as nitric acid, Fe, or Cu. |
| Tantalum (Ta) | Offers excellent corrosion resistance similar to glass. Resistant to almost all chemical media except hydrofluoric acid, fuming sulfuric acid, and alkalis. Suitable for hydrochloric acid, nitric acid, sulfuric acid below 150°C, and aqua regia. Note: Not resistant to alkalis. |
| Platinum / Iridium Alloy | Suitable for almost all chemical substances, except aqua regia and ammonium salts. |
| Stainless Steel with Tungsten Carbide Coating | Suitable for non-corrosive but highly abrasive media. |
Applicable Liners, Pressure Ratings, and Electrodes for Different Sizes
| Size Range | Pressure Rating | Available Liner Materials | Available Electrode Materials |
| DN25 mm ~ DN250 mm | 10 MPa, 16 MPa, 25 MPa, 42 MPa | FEP (F46), PFA | SUS316, Hastelloy B, Hastelloy C, Titanium, Tantalum, Stainless Steel with Tungsten Carbide Coating |
| DN3 ~ DN6 | 0.6 MPa, 1.0 MPa, 1.6 MPa, 2.5 MPa, 4.0 MPa, 6.3 MPa, 10 MPa, 16 MPa, 25 MPa, 42 MPa | FEP (F46), PFA | SUS316, Hastelloy B, Hastelloy C, Tantalum |
| DN10 ~ DN900 | 0.6 MPa, 1.0 MPa, 1.6 MPa, 2.5 MPa, 4.0 MPa, 6.3 MPa | PTFE, Polyurethane Rubber, FEP (F46), PFA, Silicone Fluorine Rubber | SUS316, Hastelloy B, Hastelloy C, Titanium, Tantalum, Stainless Steel with Tungsten Carbide Coating |
| DN40 ~ DN900 | 0.6 MPa, 1.0 MPa, 1.6 MPa, 2.5 MPa, 4.0 MPa, 6.3 MPa | Chloroprene Rubber | SUS316, Hastelloy B, Hastelloy C, Titanium, Tantalum, Stainless Steel with Tungsten Carbide Coating |
Overall Dimensions
Overall Dimensions of Flanged Type Sensor
| Nominal Diameter | Nominal Pressure | Overall Dimension(mm) | N.W | ||
| (mm) | (MPa) | L (Lined) | D | H | (kg) |
| 3 | 4 | 200 | 90 | 220 | 6 |
| 6 | 200 | 90 | 220 | 6 | |
| 10 | 200 | 90 | 220 | 6 | |
| 15 | 200 | 95 | 220 | 8 | |
| 20 | 200 | 105 | 220 | 10 | |
| 25 | 200 | 115 | 223 | 12 | |
| 32 | 200 | 140 | 240 | 13 | |
| 40 | 200 | 150 | 250 | 14 | |
| 50 | 200 | 165 | 263 | 15 | |
| 65 | 1.6 | 250 | 185 | 283 | 18 |
| 80 | 250 | 200 | 290 | 20 | |
| 100 | 250 | 235 | 318 | 25 | |
| 125 | 250 | 270 | 350 | 28 | |
| 150 | 300 | 300 | 380 | 30 | |
| 200 | 350 | 340 | 430 | 50 | |
| 250 | 450 | 405 | 495 | 70 | |
| 300 | 1 | 500 | 460 | 547 | 95 |
| 350 | 550 | 520 | 602 | 120 | |
| 400 | 600 | 580 | 665 | 140 | |
| 450 | 600 | 640 | 720 | 160 | |
| 500 | 600 | 715 | 783 | 200 | |
| 600 | 600 | 840 | 897 | 280 | |
| 700 | 700 | 895 | 982 | 350 | |
| 800 | 800 | 1050 | 1092 | 400 | |
| 900 | 900 | 1115 | 1192 | 480 | |
Connection Flange Standard: Flange Diagram
| 4.0MPa(DN3mm~DN50mm) | GB/T9119-2000 |
| 1.6MPa(DN65mm~DN250mm) | JB/T81-94 |
| 1.0MPa(DN300mm~DN900mm) | JB/T81-94 |
Flange Size
| Nomianl Pressure (Mpa) | Nominal Diameter | D(mm) | K(mm) | Φ(mm) | n | C(mm) |
| DN(mm) | ||||||
| 4 | 3 | 90 | 60 | 14 | 4 | 14 |
| 6 | 90 | 60 | 14 | 4 | 14 | |
| 10 | 90 | 60 | 14 | 4 | 14 | |
| 15 | 95 | 65 | 14 | 4 | 16 | |
| 20 | 105 | 75 | 14 | 4 | 16 | |
| 25 | 115 | 85 | 14 | 4 | 16 | |
| 32 | 135 | 100 | 18 | 4 | 18 | |
| 40 | 145 | 110 | 18 | 4 | 18 | |
| 50 | 160 | 125 | 18 | 4 | 20 | |
| 1.6 | 65 | 180 | 145 | 18 | 4 | 24 |
| 80 | 195 | 160 | 18 | 8 | 24 | |
| 100 | 215 | 180 | 18 | 8 | 26 | |
| 125 | 245 | 210 | 18 | 8 | 28 | |
| 150 | 280 | 240 | 23 | 8 | 28 | |
| 200 | 335 | 295 | 23 | 12 | 30 | |
| 250 | 405 | 355 | 25 | 12 | 32 | |
| 1.0 | 300 | 440 | 400 | 23 | 12 | 28 |
| 350 | 500 | 460 | 23 | 16 | 28 | |
| 400 | 565 | 515 | 25 | 16 | 30 | |
| 450 | 615 | 565 | 25 | 20 | 30 | |
| 500 | 670 | 620 | 25 | 20 | 32 | |
| 600 | 780 | 725 | 30 | 20 | 36 | |
| 700 | 895 | 840 | 30 | 24 | 36 | |
| 800 | 1010 | 950 | 34 | 24 | 38 | |
| 900 | 1110 | 1050 | 34 | 28 | 42 |
Chengdu Andisoon Measurement Co., Ltd. (hereinafter referred to as "Andisoon") is a wholly owned subsidiary of Houpu Clean Energy Group Co., Ltd. Established in March 2008, the company specializes in the research, development, manufacturing, and service of industrial flow measurement and clean energy equipment solutions.
Andisoon provides a wide range of products including Coriolis mass flowmeters, electromagnetic flowmeters, cryogenic submerged pumps, LNG/CNG/Hydrogen fueling equipment, loading and unloading skids, flow measurement systems, and automation control solutions. The products are widely used in oil & gas, LNG/CNG applications, hydrogen energy, chemical processing, water treatment, industrial utilities, and other process industries.
Our electromagnetic flowmeters utilize advanced digital signal processing technology with excellent anti-interference capability, high measurement accuracy, and reliable long-term operation. The products are suitable for conductive liquid measurement in water supply, wastewater treatment, chemical processing, mining, metallurgy, food & beverage, pharmaceutical, and industrial process applications.
With strong technical capabilities and extensive application experience, Andisoon provides professional product selection, customized engineering solutions, system integration, and after-sales technical support for global customers.
The company has obtained ISO 9001, ISO 14001, and ISO 45001 certifications. Products can comply with international standards and certifications including EAC, SIL2, ATEX, IECEx, PAC, QAN/QAR, and other project-specific requirements.
Relying on Houpu Group's industrial platform and global market resources, Andisoon is committed to becoming a globally competitive provider of flow measurement and clean energy equipment solutions.
Through many tests and improvements, ANDISOON summed up our experience and finally determined an inlet and outlet combined splitter cone, vacuum nickel-based brazing and heat treatment technology suitable for the CNG flowmeter produced by our company.
The measuring tube and the measuring tube joint are welded by argon arc welding; the diverter cone is inserted into the inner hole of the measuring tube joint in the axial and radial directions, and the diverter cone is positioned in conjunction with the measuring tube in the circumferential direction.
The interface joint is placed on the diverter cone, so that the outer cone surface of the diverter cone and the inner cone surface of the interface joint are positioned axially, and the inner hole of the interface joint is positioned radially. The interface joint and the diverter cone are also integrally pressed. Tight and welded with argon arc welding.
Beneficial effects:
When used in CNG flowmeters, this utility model can effectively improve the yield of CNG flowmeters, reduce the overall production cost, and scientifically ensure the overall performance of the CNG flowmeter. Moreover, this method and structure also have the characteristics of easy parts processing, low cost, and easy assembly and welding. The application of this method and structure will be of great help to the development of low-priced, high-performance domestic CNG flow meters, and will lay a solid foundation for the market dominance of domestic CNG flow meters.
After this process is applied in the production process of CNG flow meters, the deformation of the measuring tube and the uneven internal stress are minimized, which greatly improves the performance of the CNG flow meter. The yield can reach 95% and the overall cost is reduced. It is suitable for CNG flow. Large-scale mass production of CNG flow meters; it can bring the overall technology and accuracy of CNG flow meters to a new level; it will be of great help to the development of low-priced, high-performance domestic CNG flow meters and create a better market for domestic CNG flow meters. Dominance has laid a solid foundation.

FAQ - Electromagnetic Flowmeter
1. What is an electromagnetic flowmeter?
An electromagnetic flowmeter (mag flow meter) is a device used to measure the flow rate of conductive liquids based on Faraday's Law of Electromagnetic Induction. It is widely used for water, wastewater, chemicals, slurry, pulp, and other conductive media.
2. What liquids can an electromagnetic flowmeter measure?
Electromagnetic flowmeters are suitable for conductive liquids, including:
-
Water
-
Wastewater
-
Sewage
-
Acid and alkali solutions
-
Chemical liquids
-
Slurry and pulp
-
Food and beverage liquids
-
Industrial process fluids
They are not suitable for non-conductive media such as:
-
Oil
-
Gas
-
Steam
-
Pure hydrocarbons
3. What is the minimum conductivity requirement?
Most electromagnetic flowmeters require liquid conductivity greater than 5 μS/cm.
4. What are the advantages of electromagnetic flowmeters?
Main advantages include:
-
High measurement accuracy
-
No moving parts
-
Low pressure loss
-
Strong anti-interference capability
-
Wide measuring range
-
Excellent reliability
-
Suitable for corrosive media
-
Low maintenance requirement
5. What industries use electromagnetic flowmeters?
Electromagnetic flowmeters are widely used in:
-
Water treatment
-
Wastewater treatment
-
Chemical industry
-
Oil & gas auxiliary systems
-
Mining and metallurgy
-
Pulp & paper
-
Food & beverage
-
Pharmaceutical industry
-
Power plants
-
Municipal engineering
6. What pipe sizes are available?
Typical sizes range from DN10 to DN2000. Customized larger sizes are also available for special applications.
7. What accuracy can be achieved?
Standard accuracy:
-
±0.5%
Optional high accuracy:
-
±0.3%
-
±0.2% (for certain models)
8. What output signals are available?
Common output options include:
-
4-20mA
-
Pulse output
-
Frequency output
-
RS485 Modbus
-
HART communication
9. What installation types are available?
Electromagnetic flowmeters are available in:
-
Integral type
-
Remote type
-
Flange type
-
Wafer type
-
Insertion type
10. What lining materials are available?
Common lining materials include:
-
PTFE
-
PFA
-
FEP
-
Neoprene rubber
-
Polyurethane rubber
The lining material should be selected according to temperature, pressure, and chemical compatibility.
11. What electrode materials are available?
Available electrode materials include:
-
SS316L
-
Hastelloy C
-
Titanium
-
Tantalum
-
Platinum-Iridium
Material selection depends on the corrosiveness of the process fluid.
12. Can electromagnetic flowmeters measure corrosive liquids?
Yes. By selecting suitable lining and electrode materials, electromagnetic flowmeters can measure many corrosive liquids such as acids, alkalis, and salt solutions.
13. Can the flowmeter measure slurry or dirty liquids?
Yes. Since there are no obstruction parts inside the measuring tube, electromagnetic flowmeters are ideal for slurry, pulp, sewage, and particle-containing liquids.
14. Does the flowmeter require grounding?
Yes. Proper grounding is very important for stable and accurate measurement. Grounding rings or grounding electrodes may be required depending on the installation conditions.
15. What are the straight pipe requirements?
Typical installation recommendations:
-
Upstream: 5D
-
Downstream: 2D
(D = pipe diameter)
16. Can electromagnetic flowmeters measure bidirectional flow?
Yes. Most electromagnetic flowmeters support both forward and reverse flow measurement.
17. What protection ratings are available?
Typical protection grades include:
-
IP65
-
IP67
-
IP68
IP68 is suitable for underground or submerged installations.
18. What is the operating temperature range?
The temperature range depends on the lining material. Typical ranges:
-
Rubber lining: up to 80°C
-
PTFE/PFA lining: up to 180°C
19. What is the power supply requirement?
Common power supply options:
-
24VDC
-
220VAC
20. How to select the correct electromagnetic flowmeter?
The following parameters are usually required:
-
Liquid type
-
Conductivity
-
Flow range
-
Pipe size
-
Temperature
-
Pressure
-
Installation type
-
Output signal
-
Communication protocol
-
Lining and electrode material requirements
21. What certifications are available?
Products can be supplied with certifications such as:
-
ISO9001
-
CE
-
EAC
-
ATEX
-
IECEx
-
SIL2
Depending on project requirements.
22. What is the difference between an electromagnetic flowmeter and a Coriolis flowmeter?
Electromagnetic flowmeters:
-
Measure conductive liquids only
-
Lower cost for large pipe sizes
-
No pressure loss
-
Ideal for water and wastewater
Coriolis flowmeters:
-
Measure mass flow directly
-
Higher accuracy
-
Suitable for liquids and gases
-
Better for custody transfer and high-value fluids
23. Can you provide OEM or customized services?
Yes. OEM branding, customized configuration, special materials, communication protocols, and project-based solutions are available.
24. What information is required for quotation?
Please provide:
-
Medium name
-
Pipe size
-
Flow range
-
Temperature
-
Pressure
-
Connection type
-
Output signal
-
Power supply
-
Installation condition
-
Quantity required
25. How long is the delivery time?
Standard models are typically available within 7-15 working days. Customized products may require additional production time depending on specifications.
About the Supplier
This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASI248041". Items marked "" are certified.
Company Profile
Chengdu Andisoon Measurement Co., Ltd. (Andisoon) is a wholly owned subsidiary of Houpu Clean Energy Group Co., Ltd. (Stock Code: 300471). Established in 2008, Andisoon specializes in Coriolis mass flowmeters, cryogenic flow measurement, hydrogen refueling components, and industrial fluid metering solutions.
With a 25, 000 m² R&D and manufacturing facility, Andisoon develops and manufactures flow measurement and control products for demanding applications involving high pressure, low temperature, cryogenic fluids, hazardous areas, and ultra-low flow rates.
Our independently developed Coriolis mass flowmeters are designed for a wide range of challenging media and applications, including LNG, CNG, hydrogen, industrial gases, chemicals, petroleum products, and other industrial fluids. We also provide cryogenic pumps and key components for LNG, CNG, and hydrogen refueling systems.
Equipped with advanced R&D, calibration, testing, and production facilities, Andisoon provides accurate, reliable, and application-specific metering solutions for customers in the LNG, CNG, hydrogen energy, oil & gas, industrial gas, chemical, marine fuel, and environmental industries.
Andisoon operates under internationally recognized quality management systems and has obtained:
ISO 9001 - Quality Management System
ISO 14001 - Environmental Management System
ISO 45001 - Occupational Health & Safety Management System
SIL2 product certification
EAC / PAC / QAN / QAR certifications and compliance
ATEX / IECEx explosion-proof certifications available for applicable products and hazardous-area application
Our products are manufactured and tested according to applicable international standards and customer-specific technical requirements.
Global Market
Andisoon products have been exported to customers in Russia, the Netherlands, Bulgaria, France, the UAE, Thailand, Pakistan, Uzbekistan, India, Newzealand, Argentina, Chile and other countries and regions.
We support international customers with technical selection, customized configurations, OEM/ODM cooperation, project-based quotations, certification documentation, and after-sales technical support.
Main Products
Coriolis Mass Flowmeter
Industrial Coriolis Flowmeter
Chemical Coriolis Mass Flowmeter
LNG Flow Meter
CNG Mass Flowmeter
Hydrogen Flow Meter
Cryogenic Flowmeter
Cryogenic Pump
LNG Dispenser Components
CNG Dispenser Components
Hydrogen Refueling Components
Flow Measurement Skid
Industrial Fluid Metering Solutions
Why Choose Andisoon?
20+ Years of Experience
Specialized in flow measurement and fluid control technologies since 2008.
Strong R&D Capability
In-house development, calibration, testing, and engineering support for demanding applications.
Wide Application Range
Solutions for cryogenic, high-pressure, hazardous-area, chemical, hydrogen, LNG and industrial fluid applications.
International Certifications
ISO management systems and multiple international product certifications available for different markets.
OEM & Project Support
Customized products, technical documentation, OEM/ODM cooperation and project-based solutions for distributors, EPC contractors and industrial end users.
Competitive Alternative to International Brands
High-performance metering solutions with competitive pricing and responsive technical support.
About Our Factory & Business Background
-
Business Type
- Manufacturer/Factory & Trading Company
- Address
- Chengdu, Sichuan, China
-
Number of Employees
- 87
-
Registered Capital
- 50,000,000 RMB
-
Terms of Payment
- LC, T/T, D/P, PayPal, Western Union, Small-amount payment
-
International Commercial Terms(Incoterms)
- FOB, CIF, CFR, EXW
-
Average Lead Time
-
Peak Season Lead Time: 1-3 months
Off Season Lead Time: one month -
Nearest Port
- Chengdu Port
-
Minimum Order Quantity
- 1 Pc
-
Supply Chain Partners
- 136
Our Production Capability & Technical Expertise
- Main Products
- Coriolis Mass Flow Meter, LNG/ Hydrogen Refueling Nozzle, Cryogenic Submerged Pump, Break Away Coupling, Electromagnetic Flow Meter, Liquid Hydroen Refueling Nozzle, CNG/LNG/H2 Refueling Dispenser Calibrtion Device, Hydroen Air Compressor, LNG Mass Flow Meter, CNG Mass Flow Meter
-
Production Lines
- 1
-
Production Machines
- Cutting Machine, Four-column Hydraulic Press Machine, Sand Blasting Machine
-
QA/QC inspectors
- 7 people
-
Inspection Type for Finished Products
- 100% inspection(Visual inspection & Function inspection)
-
Inspection Method for Finished Products
- Have instructions and uniformly followed
-
Customization Options
- Customization from Samples, Customization from Designs, Full Customization, Flexible customization, Minor Customization
-
ODM Service Available
- Yes
-
OEM Service Available
- Yes
-
R&D Engineers
- 25 people
-
Traceability of Raw Materials
- Yes
-
Own Brand
- Yes
Our Industry Experience & Global Business Record
-
Year of Establishment
- 2008-03-20
-
Export Year
- 10 Years
-
Main Markets
- South America, Europe, Domestic
-
Annual Export Revenue
- 696,000 RMB
-
Number of Foreign Trading Staff
- 2
-
Overseas Agent/Branch
- No
FAQ
- What is an electromagnetic flowmeter?
- An electromagnetic flowmeter (mag flow meter) is a device used to measure the flow rate of conductive liquids based on Faraday's Law of Electromagnetic Induction. It is widely used for water, wastewater, chemicals, slurry, pulp, and other conductive media.
- What liquids can an electromagnetic flowmeter measure?
- Electromagnetic flowmeters are suitable for conductive liquids, including water, wastewater, sewage, acid and alkali solutions, chemical liquids, slurry and pulp, food and beverage liquids, and industrial process fluids. They are not suitable for non-conductive media such as oil, gas, steam, or pure hydrocarbons.
- What are the advantages of electromagnetic flowmeters?
- Main advantages include high measurement accuracy, no moving parts, low pressure loss, strong anti-interference capability, wide measuring range, excellent reliability, suitability for corrosive media, and low maintenance requirement.
- What industries use electromagnetic flowmeters?
- Electromagnetic flowmeters are widely used in water treatment, wastewater treatment, chemical industry, oil & gas auxiliary systems, mining and metallurgy, pulp & paper, food & beverage, pharmaceutical industry, power plants, and municipal engineering.
- What pipe sizes are available?
- Typical sizes range from DN10 to DN2000. Customized larger sizes are also available for special applications.
- What output signals are available?
- Common output options include 4-20mA, Pulse output, Frequency output, RS485 Modbus, and HART communication.
- What installation types are available?
- Electromagnetic flowmeters are available in integral type, remote type, flange type, wafer type, and insertion type.
- What lining materials are available?
- Common lining materials include PTFE, PFA, FEP, Neoprene rubber, and Polyurethane rubber. The lining material should be selected according to temperature, pressure, and chemical compatibility.
- What electrode materials are available?
- Available electrode materials include SS316L, Hastelloy C, Titanium, Tantalum, and Platinum-Iridium. Material selection depends on the corrosiveness of the process fluid.
- Can electromagnetic flowmeters measure corrosive liquids?
- Yes. By selecting suitable lining and electrode materials, electromagnetic flowmeters can measure many corrosive liquids such as acids, alkalis, and salt solutions.
- Can the flowmeter measure slurry or dirty liquids?
- Yes. Since there are no obstruction parts inside the measuring tube, electromagnetic flowmeters are ideal for slurry, pulp, sewage, and particle-containing liquids.
- Does the flowmeter require grounding?
- Yes. Proper grounding is very important for stable and accurate measurement. Grounding rings or grounding electrodes may be required depending on the installation conditions.
- What are the straight pipe requirements?
- Typical installation recommendations are 5D upstream and 2D downstream (D = pipe diameter).
- Can electromagnetic flowmeters measure bidirectional flow?
- Yes. Most electromagnetic flowmeters support both forward and reverse flow measurement.
- What protection ratings are available?
- Typical protection grades include IP65, IP67, and IP68. IP68 is suitable for underground or submerged installations.
Send your message to this supplier
People who viewed this also viewed
-
US$1,616.00 / Piece
-
US$1,286.00 / Piece
-
US$1,286.00 / Piece
-
US$1,492.00 / Piece
Product Groups
- Chemcial Flow Meter
- Electromagnetic Flow Meter
- Liquid Metering Mass Flow Meter
- Refrigerant refill mass flow meter
- Petrochemical flow measurement
- Hydrogen Compressor
- Calibration Device
- Valves
- Refueling Nozzle
- Cryogenic Submerged Pump
- High Pressure Coriolis Mass Flowmeter
- Break Away Coupling
Find Similar Products By Category
- Supplier Homepage
- Products
- Electromagnetic Flow Meter
- High-Precision Digital Flow Meter for Oil & Gas Applications
Related Categories
Hot Searches
- China Meter Factories
- Water Meter Factories
- Digital Meter Factories
- Electronic Meter Factories
- Industrial Flow Meter
- Stainless Flow Meter
- Precision Flow Meter
- Turbine Flow Meter
- Mechanical Flow Meter
- Top 10 Meter
- Meter Trends
- Digital Smart Meter Bulkbuy