Secured Trading Service

High-Precision Digital Flow Meter for Oil & Gas Applications

Chengdu Andisoon Measure Co. Ltd.
  • Audited Supplier
  • 3 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Wide Flow Range Ratio: Ratio up to 1000:1, with configurable flow velocity from 0.5m/s to 10m/s.
  • No Moving Parts Design: Zero obstruction in measuring tube, ensuring no pressure loss and minimal maintenance.
  • Corrosive Media Resistance: Compatible with acids, alkalis, and salt solutions using PTFE, PFA, or Hastelloy materials.
  • Bidirectional Flow Measurement: Supports forward, reverse, and net total flow measurement with three built-in totalizers.
  • Flexible Output Options: Offers 4-20mA, Pulse, RS485, HART, and Profibus-PA communication protocols.
  • IP68 Protection Grade: Available in IP65, IP67, and IP68 ratings for submerged or harsh environment installation.
  • Customizable Pressure Rating: Pressure ratings up to 42 MPa available, with customized options for specific needs.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of High-Precision Digital Flow Meter for Oil & Gas Applications

High-Precision Digital Flow Meter for Oil & Gas Applications
High-Precision Digital Flow Meter for Oil & Gas Applications pictures & photos
High-Precision Digital Flow Meter for Oil & Gas Applications
High-Precision Digital Flow Meter for Oil & Gas Applications pictures & photos
High-Precision Digital Flow Meter for Oil & Gas Applications
High-Precision Digital Flow Meter for Oil & Gas Applications pictures & photos
High-Precision Digital Flow Meter for Oil & Gas Applications
High-Precision Digital Flow Meter for Oil & Gas Applications pictures & photos
High-Precision Digital Flow Meter for Oil & Gas Applications
High-Precision Digital Flow Meter for Oil & Gas Applications pictures & photos
High-Precision Digital Flow Meter for Oil & Gas Applications
High-Precision Digital Flow Meter for Oil & Gas Applications pictures & photos
High-Precision Digital Flow Meter for Oil & Gas Applications
  • High-Precision Digital Flow Meter for Oil & Gas Applications
  • High-Precision Digital Flow Meter for Oil & Gas Applications
    High-Precision Digital Flow Meter for Oil & Gas Applications
  • High-Precision Digital Flow Meter for Oil & Gas Applications
    High-Precision Digital Flow Meter for Oil & Gas Applications
  • High-Precision Digital Flow Meter for Oil & Gas Applications
    High-Precision Digital Flow Meter for Oil & Gas Applications
  • High-Precision Digital Flow Meter for Oil & Gas Applications
    High-Precision Digital Flow Meter for Oil & Gas Applications
  • High-Precision Digital Flow Meter for Oil & Gas Applications
    High-Precision Digital Flow Meter for Oil & Gas Applications
  • High-Precision Digital Flow Meter for Oil & Gas Applications
    High-Precision Digital Flow Meter for Oil & Gas Applications

Find Similar Products

Product Description


AEMF Series Electromagnetic Flowmeter
Chengdu Andisoon Measure Co., Lt


 

High-Precision Digital Flow Meter for Oil & Gas Applications
High-Precision Digital Flow Meter for Oil & Gas Applications

Overview

An electromagnetic flow meter is an instrument that measures liquid flow based on Faraday's law of electromagnetic induction. It is capable of measuring the flow of various conductive liquids, such as water, wastewater, and chemical fluids.
Electromagnetic flow meters offer high accuracy, excellent stability, no moving parts, and strong resistance to media corrosion. Because of these advantages, they are widely used in industries such as water treatment, wastewater management, chemical processing, food and beverage, and pharmaceuticals for flow measurement and process control.
The working principle of an electromagnetic flow meter is based on generating a magnetic field when conductive liquid flows through a pipe. The induced voltage produced by the fluid passing through the magnetic field is proportional to the flow velocity, allowing accurate flow measurement.
Electromagnetic flow meters are available in multiple models and specifications. The appropriate type can be selected based on the properties of the liquid, flow range, and operating environment.
In summary, the electromagnetic flow meter is a high-precision, stable, and maintenance-free flow measurement instrument that is widely used for accurate measurement and control of conductive liquid flow across a broad range of industrial applications.


 

Our Advantages

High accuracy: 0.15%.The measured volumetricflow rate is not affected by fluid density,viscosity,temperature orpressure.

Noclogdesign:  Lower pressureloss.

Bidirectional Flow Measurement: Capable of  measuringflowin

Best choice for corrosive  process fluids: Various electrodes and linings,suitable fo all typesof conductive corrosive  liquids such as acids,alkalis,and salt solutions.

Wide range ratio: 20:1 to 1000:1,with selectable wide flow ranges.The full-scale liquid flow velocity can be configured between 0.5m/s and
10m/s.

Easy installation: Lower requirements forstraight pipe line,5Dupstream straight pipe,2D downstream straight pipe.

Wideline size: DN 3mm to DN 3000mm.

Product Description

·Measurement accuracy is not affected by changes in fluid density, viscosity, temperature, pressure, or electrical conductivity, ensuring stable performance in various applications

·The measuring tube has no obstructing moving parts and causes no pressure loss, helping reduce energy consumption.

·Low requirements for straight pipe sections, saving installation space.

·The converter uses an LCD backlit display, ensuring easy reading in both direct sunlight and dark environments.

·Parameters can be configured via infrared touch buttons, allowing safe operation without opening the converter cover even in harsh environments.

·The flow meter supports bidirectional measurement and includes three built-in totalizers: forward total, reverse total, and net total, with display of both forward and reverse flow.

·Multiple output options are available, including current output, frequency/pulse output, HART communication, and RS485 digital communication.

·Equipped with self-diagnostic alarm functions, empty pipe detection, and high/low flow alarm outputs.

·Suitable not only for general process monitoring but also for measuring slurries, pulp, and viscous fluids.

Measurement Principle

The measurement principle is based on Faraday's law of electromagnetic induction. When a conductor moves through a magnetic field and cuts magnetic flux lines, an electromotive force is generated in the conductor. The induced electromotive force E is expressed as:

E = K B V D
K: Instrument constant
B: Magnetic flux density
V: Average flow velocity across the cross-section of the measuring tube
D: Inner diameter of the measuring tube
High-Precision Digital Flow Meter for Oil & Gas Applications
 

Product Parameters

Nominal Diameter DN3~DN3000
Pressure limited Maximum 42 MPa
Accuracy ±0.5% of reading(±0.2%,±0.3%Optional)
Liner Materials PTFE,PFA,F46,chloroprene rubber,silicone fluorine rubber,polyurethane rubber
Electrode Type Standard type,scraper type
Electrode Materials 316L,Hastelloy C,Hastelloy B,Titanium,Tantalum,Platinum-Iridium alloy,316L
  coated with tungsten carbide
Medium Temperature -40ºC~180ºC
  -40°ºC~180ºC(Related to liner)
Ambient Temperature -40ºC~60ºC
Ambient Humidity 5%-95%non-condensing
Conductivity ≥20μs/cm
Flow Range 1000:1(flow rate <15m/s)
Structure integral type,remote type,immersion type,explosion-proof type
Conduit M20*1,5F,1/2NPTF
Enclosure IP65,IP66,IP67,IP68  IP65,IP66,IP67,IP68 optional
Installation Type flange type,wafer type,insert type
Output Signal pulse+4~20mA+HART,Pulse+4~20mA+RS485,Profibus-PA
Power Supply 220VAC/50Hz,24VDC,3.6V Lithium battery
Explosion-Proof Exdb ia[iaGa]qII CT6Gb
certification  
Product Standard JB/T2948-2015


Converter Performance Parameters

Power Supply AC 220V 50Hz / DC 24V / 3.6V battery powered
Power Consumption Power Consumption
Power Consumption Bilingual (Chinese/English) display; shows instantaneous flow, total flow, and alarm status (excitation circuit failure alarm, empty pipe alarm, flow limit alarm); equipped with four membrane touch keys for parameter setting
Totalizer Forward total, reverse total, net (difference) total





Output Signals
Analog Output
 
4~20mADC;Load Resistance:0~750Ω
 

Frequency/Pulse Output
Used for forward or reverse instantaneous flow measurement; range: 1-5000 Hz or up to 5000 pulses/s; electrical isolation via optocoupler, isolation voltage >1000 VDC; output driver: MOSFET output, max voltage 35 VDC, max load current 250 mA
     range: 1-5000 Hz or up to 5000 pulses/s; output driver:
    electrical isolation via optocoupler, isolation voltage >1000 VDC;
    MOSFET output, max voltage 35 VDC, max load current 250 mA
 
Alarm Output(Optional)
Used for high/low flow limit alarms; output driver:
    electrical isolation via optocoupler, isolation voltage >1000 VDC;
    MOSFET output, max voltage 35 VDC, max load current 250 mA
  Communication Optional RS485 / HART communication
Accuracy Optional RS485 / HART communication
Damping Time Adjustable from 0-100 s (90% response time, segmented settings available)
Lightning Protection Yes
Lightning Protection Built-in non-volatile clock; stores up to 16 power-off records (10-year retention)
Protection Class IP65
Explosion-proof Marking Ex db ia [ia Ga] q IIC T6 Gb
 
Flange-Type Sensor Performance Parameters
 
Parameter Specification
Nominal Diameter DN3 mm - DN900 mm
Nominal Pressure 0.6 - 4.0 MPa (custom higher pressure available)
Accuracy ±0.5% of reading; optional ±0.3% or ±0.2% of reading
Liner Materials Chloroprene rubber, polyurethane rubber, fluorosilicone rubber, PTFE, FEP (F46), PFA
Electrode Types Standard type, scraper type, replaceable type (customizable)
Electrode Materials SS316L, Hastelloy B, Hastelloy C, titanium, tantalum, Monel, platinum/iridium alloy, stainless steel coated with tungsten carbide
 
 
High Pressure Type Sensor Technical Specifications
 
Item Specification
Nominal Diameter DN25 mm ~ DN250 mm
Nominal Pressure 6.3 MPa, 10 MPa, 16 MPa, 25 MPa, 42 MPa
Accuracy ±0.5% of reading, optional ±0.3% or ±0.2% of reading
Liner Materials PTFE (Polytetrafluoroethylene), FEP (F46), PFA
Electrode Materials SUS316, Hastelloy B, Hastelloy C, Titanium, Stainless Steel with Tungsten Carbide Coating
Structure Type Integral type, split type
Medium Temperature (FEP / PFA Lining) -10°C ~ +160°C
Medium Temperature (PTFE Lining) -10°C ~ +120°C
Ambient Temperature -25°C ~ +60°C
Medium Conductivity ≥20 μS/cm
Connection Type Flange type, Hammer Union type
Product Standard JB/T9248-2015 Electromagnetic Flowmeter
 
 
Electrode Material Corrosion Resistance
 
Electrode Material Corrosion Resistance Characteristics
SUS316 Suitable for industrial water, potable water, wastewater, and mildly corrosive media. Widely used in petroleum, chemical, steel industries, as well as municipal and environmental protection applications.
Hastelloy B (HB) Resistant to non-oxidizing acids such as hydrochloric acid, sulfuric acid, phosphoric acid, hydrofluoric acid, organic acids, as well as alkalis and non-oxidizing salt solutions at room temperature.
Hastelloy C (HC) Resistant to oxidizing salts such as Fe and Cu salts or media containing other oxidizing agents. Also resistant to hypochlorite solutions and seawater corrosion.
Titanium (Ti) Resistant to seawater, various chlorides and hypochlorites, oxidizing acids (including fuming sulfuric acid), organic acids, and alkalis. However, corrosion resistance decreases significantly in acids containing oxidizing agents such as nitric acid, Fe, or Cu.
Tantalum (Ta) Offers excellent corrosion resistance similar to glass. Resistant to almost all chemical media except hydrofluoric acid, fuming sulfuric acid, and alkalis. Suitable for hydrochloric acid, nitric acid, sulfuric acid below 150°C, and aqua regia. Note: Not resistant to alkalis.
Platinum / Iridium Alloy Suitable for almost all chemical substances, except aqua regia and ammonium salts.
Stainless Steel with Tungsten Carbide Coating Suitable for non-corrosive but highly abrasive media.

Applicable Liners, Pressure Ratings, and Electrodes for Different Sizes
 
Size Range Pressure Rating Available Liner Materials Available Electrode Materials
DN25 mm ~ DN250 mm 10 MPa, 16 MPa, 25 MPa, 42 MPa FEP (F46), PFA SUS316, Hastelloy B, Hastelloy C, Titanium, Tantalum, Stainless Steel with Tungsten Carbide Coating
DN3 ~ DN6 0.6 MPa, 1.0 MPa, 1.6 MPa, 2.5 MPa, 4.0 MPa, 6.3 MPa, 10 MPa, 16 MPa, 25 MPa, 42 MPa FEP (F46), PFA SUS316, Hastelloy B, Hastelloy C, Tantalum
DN10 ~ DN900 0.6 MPa, 1.0 MPa, 1.6 MPa, 2.5 MPa, 4.0 MPa, 6.3 MPa PTFE, Polyurethane Rubber, FEP (F46), PFA, Silicone Fluorine Rubber SUS316, Hastelloy B, Hastelloy C, Titanium, Tantalum, Stainless Steel with Tungsten Carbide Coating
DN40 ~ DN900 0.6 MPa, 1.0 MPa, 1.6 MPa, 2.5 MPa, 4.0 MPa, 6.3 MPa Chloroprene Rubber SUS316, Hastelloy B, Hastelloy C, Titanium, Tantalum, Stainless Steel with Tungsten Carbide Coating

Overall Dimensions
Flanged Type Sensor Outline Drawing
High-Precision Digital Flow Meter for Oil &amp; Gas Applications
High-Precision Digital Flow Meter for Oil &amp; Gas Applications

Overall Dimensions of Flanged Type Sensor
 
Nominal Diameter Nominal Pressure Overall Dimension(mm) N.W
(mm) (MPa) L (Lined) D H (kg)
3 4 200 90 220 6
6 200 90 220 6
10 200 90 220 6
15 200 95 220 8
20 200 105 220 10
25 200 115 223 12
32 200 140 240 13
40 200 150 250 14
50 200 165 263 15
65 1.6 250 185 283 18
80 250 200 290 20
100 250 235 318 25
125 250 270 350 28
150 300 300 380 30
200 350 340 430 50
250 450 405 495 70
300 1 500 460 547 95
350 550 520 602 120
400 600 580 665 140
450 600 640 720 160
500 600 715 783 200
600 600 840 897 280
700 700 895 982 350
800 800 1050 1092 400
900 900 1115 1192 480
Note: For pressure ratings within 4.0 MPa, instruments with the same nominal diameter have identical face-to-face lengths regardless of pressure class. For other specific dimensions, please consult the manufacturer.

Connection Flange Standard:                                                                                    Flange Diagram
4.0MPa(DN3mm~DN50mm) GB/T9119-2000
1.6MPa(DN65mm~DN250mm) JB/T81-94
1.0MPa(DN300mm~DN900mm) JB/T81-94
High-Precision Digital Flow Meter for Oil &amp; Gas Applications

Flange Size
 
Nomianl Pressure (Mpa) Nominal Diameter D(mm) K(mm) Φ(mm) n C(mm)
DN(mm)
4 3 90 60 14 4 14
6 90 60 14 4 14
10 90 60 14 4 14
15 95 65 14 4 16
20 105 75 14 4 16
25 115 85 14 4 16
32 135 100 18 4 18
40 145 110 18 4 18
50 160 125 18 4 20
1.6 65 180 145 18 4 24
80 195 160 18 8 24
100 215 180 18 8 26
125 245 210 18 8 28
150 280 240 23 8 28
200 335 295 23 12 30
250 405 355 25 12 32
1.0  300 440 400 23 12 28
350 500 460 23 16 28
400 565 515 25 16 30
450 615 565 25 20 30
500 670 620 25 20 32
600 780 725 30 20 36
700 895 840 30 24 36
800 1010 950 34 24 38
900 1110 1050 34 28 42


 

Company Profile

Chengdu Andisoon Measurement Co., Ltd. (hereinafter referred to as "Andisoon") is a wholly owned subsidiary of Houpu Clean Energy Group Co., Ltd. Established in March 2008, the company specializes in the research, development, manufacturing, and service of industrial flow measurement and clean energy equipment solutions.

Andisoon provides a wide range of products including Coriolis mass flowmeters, electromagnetic flowmeters, cryogenic submerged pumps, LNG/CNG/Hydrogen fueling equipment, loading and unloading skids, flow measurement systems, and automation control solutions. The products are widely used in oil & gas, LNG/CNG applications, hydrogen energy, chemical processing, water treatment, industrial utilities, and other process industries.

Our electromagnetic flowmeters utilize advanced digital signal processing technology with excellent anti-interference capability, high measurement accuracy, and reliable long-term operation. The products are suitable for conductive liquid measurement in water supply, wastewater treatment, chemical processing, mining, metallurgy, food & beverage, pharmaceutical, and industrial process applications.

With strong technical capabilities and extensive application experience, Andisoon provides professional product selection, customized engineering solutions, system integration, and after-sales technical support for global customers.

The company has obtained ISO 9001, ISO 14001, and ISO 45001 certifications. Products can comply with international standards and certifications including EAC, SIL2, ATEX, IECEx, PAC, QAN/QAR, and other project-specific requirements.

Relying on Houpu Group's industrial platform and global market resources, Andisoon is committed to becoming a globally competitive provider of flow measurement and clean energy equipment solutions.

 

Why choose us?

Through many tests and improvements, ANDISOON summed up our experience and finally determined an inlet and outlet combined splitter cone, vacuum nickel-based brazing and heat treatment technology suitable for the CNG flowmeter produced by our company.

1. Imported combined splitter cone (obtained utility model patent - patent number: 201020170649.5)
The inlet end and the outlet end are structurally symmetrical and are connected by a pipe body. The inlet end and the outlet end are composed of an interface joint, a shunt cone, two measuring tubes and a measuring tube joint, wherein the interface joint and the measuring tube joint form a The two are docked and positioned with a shunt cone. The measuring tube is inserted into the measuring pipe joint and then welded. The shunt cone is inserted into the measuring tube and the measuring pipe joint. The measuring tube and the shunt cone maintain a tight positioning fit.
The measuring tube and the measuring tube joint are welded by argon arc welding; the diverter cone is inserted into the inner hole of the measuring tube joint in the axial and radial directions, and the diverter cone is positioned in conjunction with the measuring tube in the circumferential direction.
The interface joint is placed on the diverter cone, so that the outer cone surface of the diverter cone and the inner cone surface of the interface joint are positioned axially, and the inner hole of the interface joint is positioned radially. The interface joint and the diverter cone are also integrally pressed. Tight and welded with argon arc welding.

Beneficial effects:
When used in CNG flowmeters, this utility model can effectively improve the yield of CNG flowmeters, reduce the overall production cost, and scientifically ensure the overall performance of the CNG flowmeter. Moreover, this method and structure also have the characteristics of easy parts processing, low cost, and easy assembly and welding. The application of this method and structure will be of great help to the development of low-priced, high-performance domestic CNG flow meters, and will lay a solid foundation for the market dominance of domestic CNG flow meters.
2. Vacuum nickel-based brazing and heat treatment (obtained invention patent - patent number: 201010186127.9)
This process is completed according to the process flow of parts positioning, parts calibration, surface treatment, solder laying, vacuum welding and vacuum insulation, and cooling out of the furnace. It effectively solves the problem of CNG flowmeter failure caused by uneven heating of the measuring tube due to conventional silver-based manual soldering. Performance is greatly reduced.
After this process is applied in the production process of CNG flow meters, the deformation of the measuring tube and the uneven internal stress are minimized, which greatly improves the performance of the CNG flow meter. The yield can reach 95% and the overall cost is reduced. It is suitable for CNG flow. Large-scale mass production of CNG flow meters; it can bring the overall technology and accuracy of CNG flow meters to a new level; it will be of great help to the development of low-priced, high-performance domestic CNG flow meters and create a better market for domestic CNG flow meters. Dominance has laid a solid foundation.
3. High-precision time difference detection technology
It is used for high-precision time difference testing of mass flow meters. The time difference measurement can reach within 0.3 nanoseconds, ensuring high accuracy of measurement; it adopts DSP (digital signal processing) technology and can effectively replace imported products.
1) Adaptive linear digital filtering technology
It can filter out the interference waveform of the output current of the mass flow meter sensor. Linear filtering does not affect the linear characteristics of the flow meter. In addition, because the transmitter needs to adapt to sensors with multiple natural frequencies, an adaptive algorithm is designed to achieve frequency adaptation. Ensure the versatility of the filtering algorithm.
2) Weak signal detection circuit based on high-precision differential analog operational amplifier
It belongs to the circuit design of the mass flow meter. The design of the voltage follower prevents the output from affecting the input. The design of the differential circuit effectively suppresses common mode interference signals. It has strong anti-interference performance, low detection signal amplitude and high accuracy.
3) Adaptive broadband oscillation technology based on frequency sweep algorithm
Used for mass flow meters, it has a wide frequency sweep range and fast frequency sweep speed, effectively ensuring the detection of the center frequency. Different sensors can be set to different frequency sweep ranges.
4) Synchronous phase tracking technology for constant measurement of tube resonance amplitude
It is used in mass flow meters to ensure that the resonance amplitude of the measuring tube is stable, the fluctuation is small, and the phase synchronization can be achieved within 6°.
 
 

Certifications

High-Precision Digital Flow Meter for Oil &amp; Gas Applications

FAQ

FAQ - Electromagnetic Flowmeter

1. What is an electromagnetic flowmeter?

An electromagnetic flowmeter (mag flow meter) is a device used to measure the flow rate of conductive liquids based on Faraday's Law of Electromagnetic Induction. It is widely used for water, wastewater, chemicals, slurry, pulp, and other conductive media.

2. What liquids can an electromagnetic flowmeter measure?

Electromagnetic flowmeters are suitable for conductive liquids, including:

  • Water

  • Wastewater

  • Sewage

  • Acid and alkali solutions

  • Chemical liquids

  • Slurry and pulp

  • Food and beverage liquids

  • Industrial process fluids

They are not suitable for non-conductive media such as:

  • Oil

  • Gas

  • Steam

  • Pure hydrocarbons

 

3. What is the minimum conductivity requirement?

Most electromagnetic flowmeters require liquid conductivity greater than 5 μS/cm.

 

4. What are the advantages of electromagnetic flowmeters?

Main advantages include:

  • High measurement accuracy

  • No moving parts

  • Low pressure loss

  • Strong anti-interference capability

  • Wide measuring range

  • Excellent reliability

  • Suitable for corrosive media

  • Low maintenance requirement

 

5. What industries use electromagnetic flowmeters?

Electromagnetic flowmeters are widely used in:

  • Water treatment

  • Wastewater treatment

  • Chemical industry

  • Oil & gas auxiliary systems

  • Mining and metallurgy

  • Pulp & paper

  • Food & beverage

  • Pharmaceutical industry

  • Power plants

  • Municipal engineering

 

6. What pipe sizes are available?

Typical sizes range from DN10 to DN2000. Customized larger sizes are also available for special applications.

 

7. What accuracy can be achieved?

Standard accuracy:

  • ±0.5%

Optional high accuracy:

  • ±0.3%

  • ±0.2% (for certain models)

8. What output signals are available?

Common output options include:

  • 4-20mA

  • Pulse output

  • Frequency output

  • RS485 Modbus

  • HART communication

9. What installation types are available?

Electromagnetic flowmeters are available in:

  • Integral type

  • Remote type

  • Flange type

  • Wafer type

  • Insertion type

10. What lining materials are available?

Common lining materials include:

  • PTFE

  • PFA

  • FEP

  • Neoprene rubber

  • Polyurethane rubber

The lining material should be selected according to temperature, pressure, and chemical compatibility.

11. What electrode materials are available?

Available electrode materials include:

  • SS316L

  • Hastelloy C

  • Titanium

  • Tantalum

  • Platinum-Iridium

Material selection depends on the corrosiveness of the process fluid.

12. Can electromagnetic flowmeters measure corrosive liquids?

Yes. By selecting suitable lining and electrode materials, electromagnetic flowmeters can measure many corrosive liquids such as acids, alkalis, and salt solutions.

13. Can the flowmeter measure slurry or dirty liquids?

Yes. Since there are no obstruction parts inside the measuring tube, electromagnetic flowmeters are ideal for slurry, pulp, sewage, and particle-containing liquids.

14. Does the flowmeter require grounding?

Yes. Proper grounding is very important for stable and accurate measurement. Grounding rings or grounding electrodes may be required depending on the installation conditions.

15. What are the straight pipe requirements?

Typical installation recommendations:

  • Upstream: 5D

  • Downstream: 2D

(D = pipe diameter)

 

16. Can electromagnetic flowmeters measure bidirectional flow?

Yes. Most electromagnetic flowmeters support both forward and reverse flow measurement.

17. What protection ratings are available?

Typical protection grades include:

  • IP65

  • IP67

  • IP68

IP68 is suitable for underground or submerged installations.

18. What is the operating temperature range?

The temperature range depends on the lining material. Typical ranges:

  • Rubber lining: up to 80°C

  • PTFE/PFA lining: up to 180°C

19. What is the power supply requirement?

Common power supply options:

  • 24VDC

  • 220VAC

20. How to select the correct electromagnetic flowmeter?

The following parameters are usually required:

  • Liquid type

  • Conductivity

  • Flow range

  • Pipe size

  • Temperature

  • Pressure

  • Installation type

  • Output signal

  • Communication protocol

  • Lining and electrode material requirements

21. What certifications are available?

Products can be supplied with certifications such as:

  • ISO9001

  • CE

  • EAC

  • ATEX

  • IECEx

  • SIL2

Depending on project requirements.

 

22. What is the difference between an electromagnetic flowmeter and a Coriolis flowmeter?

Electromagnetic flowmeters:

  • Measure conductive liquids only

  • Lower cost for large pipe sizes

  • No pressure loss

  • Ideal for water and wastewater

Coriolis flowmeters:

  • Measure mass flow directly

  • Higher accuracy

  • Suitable for liquids and gases

  • Better for custody transfer and high-value fluids

 

23. Can you provide OEM or customized services?

Yes. OEM branding, customized configuration, special materials, communication protocols, and project-based solutions are available.

 

24. What information is required for quotation?

Please provide:

  • Medium name

  • Pipe size

  • Flow range

  • Temperature

  • Pressure

  • Connection type

  • Output signal

  • Power supply

  • Installation condition

  • Quantity required

 

25. How long is the delivery time?

Standard models are typically available within 7-15 working days. Customized products may require additional production time depending on specifications.

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASI248041". Items marked "verified" are certified.

Watch Video
Watch Video
Chengdu Andisoon Measure Co. Ltd.
Chengdu Andisoon Measure Co. Ltd.
Chengdu Andisoon Measure Co. Ltd.
Chengdu Andisoon Measure Co. Ltd.
Chengdu Andisoon Measure Co. Ltd.
Chengdu Andisoon Measure Co. Ltd.
Chengdu Andisoon Measure Co. Ltd.
Chengdu Andisoon Measure Co. Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
Chengdu, Sichuan, China
verified Number of Employees
87
verified Registered Capital
50,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: 1-3 months
Off Season Lead Time: one month
verified Nearest Port
Chengdu Port
verified Minimum Order Quantity
1 Pc
verified Supply Chain Partners
136

Our Production Capability & Technical Expertise

Main Products
Coriolis Mass Flow Meter, LNG/ Hydrogen Refueling Nozzle, Cryogenic Submerged Pump, Break Away Coupling, Electromagnetic Flow Meter, Liquid Hydroen Refueling Nozzle, CNG/LNG/H2 Refueling Dispenser Calibrtion Device, Hydroen Air Compressor, LNG Mass Flow Meter, CNG Mass Flow Meter
verified Production Lines
1
verified Production Machines
Cutting Machine, Four-column Hydraulic Press Machine, Sand Blasting Machine
verified QA/QC inspectors
7 people
verified Inspection Type for Finished Products
100% inspection(Visual inspection & Function inspection)
verified Inspection Method for Finished Products
Have instructions and uniformly followed
verified Customization Options
Customization from Samples, Customization from Designs, Full Customization, Flexible customization, Minor Customization
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
25 people
verified Traceability of Raw Materials
Yes
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2008-03-20
verified Export Year
10 Years
verified Main Markets
South America, Europe, Domestic
verified Annual Export Revenue
696,000 RMB
verified Number of Foreign Trading Staff
2
verified Overseas Agent/Branch
No

FAQ

What is an electromagnetic flowmeter?
An electromagnetic flowmeter (mag flow meter) is a device used to measure the flow rate of conductive liquids based on Faraday's Law of Electromagnetic Induction. It is widely used for water, wastewater, chemicals, slurry, pulp, and other conductive media.
What liquids can an electromagnetic flowmeter measure?
Electromagnetic flowmeters are suitable for conductive liquids, including water, wastewater, sewage, acid and alkali solutions, chemical liquids, slurry and pulp, food and beverage liquids, and industrial process fluids. They are not suitable for non-conductive media such as oil, gas, steam, or pure hydrocarbons.
What are the advantages of electromagnetic flowmeters?
Main advantages include high measurement accuracy, no moving parts, low pressure loss, strong anti-interference capability, wide measuring range, excellent reliability, suitability for corrosive media, and low maintenance requirement.
What industries use electromagnetic flowmeters?
Electromagnetic flowmeters are widely used in water treatment, wastewater treatment, chemical industry, oil & gas auxiliary systems, mining and metallurgy, pulp & paper, food & beverage, pharmaceutical industry, power plants, and municipal engineering.
What pipe sizes are available?
Typical sizes range from DN10 to DN2000. Customized larger sizes are also available for special applications.
What output signals are available?
Common output options include 4-20mA, Pulse output, Frequency output, RS485 Modbus, and HART communication.
What installation types are available?
Electromagnetic flowmeters are available in integral type, remote type, flange type, wafer type, and insertion type.
What lining materials are available?
Common lining materials include PTFE, PFA, FEP, Neoprene rubber, and Polyurethane rubber. The lining material should be selected according to temperature, pressure, and chemical compatibility.
What electrode materials are available?
Available electrode materials include SS316L, Hastelloy C, Titanium, Tantalum, and Platinum-Iridium. Material selection depends on the corrosiveness of the process fluid.
Can electromagnetic flowmeters measure corrosive liquids?
Yes. By selecting suitable lining and electrode materials, electromagnetic flowmeters can measure many corrosive liquids such as acids, alkalis, and salt solutions.
Can the flowmeter measure slurry or dirty liquids?
Yes. Since there are no obstruction parts inside the measuring tube, electromagnetic flowmeters are ideal for slurry, pulp, sewage, and particle-containing liquids.
Does the flowmeter require grounding?
Yes. Proper grounding is very important for stable and accurate measurement. Grounding rings or grounding electrodes may be required depending on the installation conditions.
What are the straight pipe requirements?
Typical installation recommendations are 5D upstream and 2D downstream (D = pipe diameter).
Can electromagnetic flowmeters measure bidirectional flow?
Yes. Most electromagnetic flowmeters support both forward and reverse flow measurement.
What protection ratings are available?
Typical protection grades include IP65, IP67, and IP68. IP68 is suitable for underground or submerged installations.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now