Atex Approve DN 25 Coriolis Mass Flowmeter for LNG Application

Product Details
Customization: Available
After-sales Service: on Line
Warranty: 12 Months
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Patents Awarded
The supplier had awarded 2 patents, you can check the Audit Report for more information
National Award received
This supplier had received national award, you can check the Audit Report for more information
100% Finished Products Inspection
The supplier inspects 100% of finished products.
Production Process Visualization
You can check the supplier's production workflow chart or main facilities in the Audit Report
to see all verified strength labels (26)
  • Atex Approve DN 25 Coriolis Mass Flowmeter for LNG Application
  • Atex Approve DN 25 Coriolis Mass Flowmeter for LNG Application
  • Atex Approve DN 25 Coriolis Mass Flowmeter for LNG Application
  • Atex Approve DN 25 Coriolis Mass Flowmeter for LNG Application
  • Atex Approve DN 25 Coriolis Mass Flowmeter for LNG Application
Find Similar Products
  • Overview
  • Our Advantages
Overview

Basic Info.

Model NO.
AMF025AN
Size
DN10-50
Sensor
Clamp-on/External
Application
Energy Metering
Type
Coriolis Mass Flow Meter
Measuring Media
Liquid
Measuring Principle
Coriolis
Measurement Object
Open Channel
Certification
JIS, DIN, CE, ISO
Repeatability
0.05% (Optional), 0.075%, 0.1%, 025%(Default)
Density
0.001g/cm3
Measuring Medium
Gas, Liquid and Multi-Phase Flow
Wetting Material
SS304, SS316L
Transport Package
1 Piece / Carton
Trademark
Andisoon
Origin
China
HS Code
9026801000
Production Capacity
100000 Pices/Year

Product Description

Coriolis mass flowmeter of LNG application

Atex Approve DN 25 Coriolis Mass Flowmeter for LNG Application

Atex Approve DN 25 Coriolis Mass Flowmeter for LNG Application
Coriolis mass flowmeter can directly measure the mass flow-rate, density and temperature of the flowing medium.

The flowmeter is an intelligent meter with digital signal processing as the core, thus a dozen of parameters can be outputted for user according to the three fundamental quantities above. Featured with flexible configuration, strong function and high cost perfomance, the Coriolis Mass Flowmeter is a new generation of high-precision flow meter. Coriolis Mass Flowmeter is a new generation of high-precision flow meter, which is flexible configuration, powerful function and high cost perfomance.

Atex Approve DN 25 Coriolis Mass Flowmeter for LNG ApplicationAtex Approve DN 25 Coriolis Mass Flowmeter for LNG Application
 Atex Approve DN 25 Coriolis Mass Flowmeter for LNG Application

Andisoon mass flow meter  passed ATEX, CCS, IECEx and PESO certificates.

It can be used to directly measure the mass flow rate of fluid in pipeline without the influence of temperature, pressure and flow velocity.
High accuracy and excellent repeatability. Wide range ratio (100:1).
Cryogenic and high pressure calibration is employed for high -pressure flowmeter. Compact structure and strong installation interchangeability. Small pressure loss and wide range of working conditions.
The hydrogen mass flowmeter has excellent small flow measurement performance, which can fully meet the working conditions of the hydrogen dispensers. There are currently two types of hydrogen mass flowmeters: 35MPa and 70MPa (rated operating pressure). Due to the high safety requirements of hydrogen flowmeter, we have obtained the IIC explosion-proof certificate.

Atex Approve DN 25 Coriolis Mass Flowmeter for LNG Application
Accuracy  0.1% (Optional), 0.15%, 0.2%, 0.5% (Default)
Repeatability 0.05% (Optional), 0.075%, 0.1%, 025%(Default)
Density ±0.001g/cm3
Temp. ±1°C
Answer the liquid material   304 , 316L, ( Customizable: Monel 400, Hastelloy C22 , etc.)
Measuring medium  Gas, Liquid and Multi-phase flow

 


Model
AMF025AN
Nominal diameter DN25
Measuring medium Liquid ,Gas
Medium temp.range - 196ºC~+70ºC
Max.Flow-rate 80kg/min
Working Pressure range
(Customizanle)
4Map
Connection Mode
(Customizanle)
HG/T 20592, DN25
PN40 (RF) ,WN
Liquid Trough Materrial 304 ,316L
Safety and Protection IP67 Ex ib II C T6 Gb CCS ATEX
 

Atex Approve DN 25 Coriolis Mass Flowmeter for LNG Application
Coriolis mass flowmeters are widely utilized in LNG dispenser applications due to their precision and dependability in measuring LNG mass flow. In this context, a Coriolis mass flowmeter is employed to measure the mass flow of LNG as it is dispensed from the storage tank into a vehicle or container, ensuring accurate delivery. Additionally, these flowmeters can measure the density of the LNG, crucial for determining energy content and quality, essential for billing and equipment functionality. Furthermore, they can compensate for temperature and pressure variations, ensuring accurate mass flow measurement under changing conditions. Known for their robustness, Coriolis mass flowmeters are suitable for use in LNG dispensers, where safety and reliability are paramount.


Our Advantages

UNIQUE FEATURES OF ANDISOON MASS FLOWMETER


Mass flow meters are known for their high accuracy, wide measuring range and reliable performance, and have been successfully used in various industries over the past many years.

Unlike other instruments that are limited to measuring liquids at normal pressure and temperature, ANDISOON excels in measuring under challenging conditions, including high pressure, high viscosity, and high and low temperatures. For example, when measuring CNG (compressed natural gas), the difficulty lies in the high pressure.

However, ANDISOON's sensors can withstand high pressures, allowing the necessary increase in flow tube thickness, allowing the transmitter to detect signals with greater sensitivity. Therefore, ANDISOON's mass flow meters specially designed for CNG gas dispensers have been widely used in the  market.

In the field of cryogenics, Andisoon has developed a backflow meter and a liquid phase injection meter for LNG refueling stations, with a minimum temperature of -196°C.

In the field of process control, Andisoon has developed a micro-bend type mass flowmeter, with a maximum flow rate of up to 300t/h, widely used in petroleum, chemical and other industrial conditions.


A. ANDISOON mass flowmeter directly measures the mass flow rate, it is measured in terms of standard volume alone. Bits provide output without the need to compensate for variable pressure or temperature in the flow computer.
In addition, because ANDISOON flowmeters have no wearable moving parts and calibration will not change over time,
changes, so they require no routine maintenance.
B. ANDISOON R& D team is Using hardware DSP data processing technology
Our company adopts the world's most advanced second-generation transmitter technology - DSP processing technology, which has higher measurement accuracy, wider range, simpler structure and more stable operation.
C. Can measure high pressure gas
The application of domestic mass flow meters is mainly concentrated in the field of liquid measurement, and there is no mature application in the field of gas measurement. On the basis of mastering DSP processing technology, our company complies with the needs of the industry and designs a high-precision mass flow meter suitable for high-pressure gas measurement, which is more suitable for the needs of the high-pressure gas measurement industry and has better performance.
D. Industry-leading high-pressure aging process
The high-pressure aging platform built by our company conducts aging tests on each CNG flow meter, providing an effective solution to the problem of measurement performance degradation that may be caused by changes in sensor characteristics due to long-term high pressure during later use.
E. Good zero point stability
Our company has designed a set of high-precision processing technology for the manufacturing of sensors to ensure the quality of the sensor, and its zero-point stability is not inferior to imported products.
F. Multi-parameter measurement technology
Our company adopts digital signal processing (DSP) technology. Compared with analog technology, front-end digital processing equipment significantly reduces signal noise and responds faster. It adopts 485 communication. The host side of the metering system can obtain the required relevant parameters through 485 communication. , such as: mass flow, volume flow, temperature, density, status and other information. For liquid applications, mass flow meters using multi-parameter measurement technology can achieve an accuracy of 0.2. The actual accuracy can be higher and the performance can be even better.   
G. Self-diagnosis technology
In the actual application process, when an abnormality occurs in the flow meter, the fault code can be read through debugging software or handheld debugging equipment, which facilitates flow meter users to solve the problem more comprehensively and eliminate faults.
H. Supports standard industrial control communication protocols ModbusRTU, etc., making it easy to configure and use.
 I. Industry-leading cryogenic calibration platform
In the process of LNG development, the company has built an industry-leading cryogenic calibration platform, using liquid nitrogen (-196°C) with a lower temperature than LNG as the calibration medium, providing a cryogenic solution for the development of LNG Coriolis flowmeters. Application experience. This calibration platform has now been used as the calibration platform for all the company's LNG flow meters, enabling real cryogenic calibration of each LNG flow meter to ensure the measurement accuracy of cryogenic applications.
J. Good scalability
The company can design and manufacture mass flow meters with special specifications and models and special functions according to user needs, tailor-made for users.
Atex Approve DN 25 Coriolis Mass Flowmeter for LNG ApplicationAtex Approve DN 25 Coriolis Mass Flowmeter for LNG Application

Atex Approve DN 25 Coriolis Mass Flowmeter for LNG Application
Atex Approve DN 25 Coriolis Mass Flowmeter for LNG Application
Atex Approve DN 25 Coriolis Mass Flowmeter for LNG Application
A. The optimal vibration mode of flowmeters is determined after the finitement analysis, the structure is improved and the modal in each order is reasonably distributed. Driven by the simple harmonic, each position of the measuring tube will respond. A reasonable damped structure has been designed to improve the noise-proof feature.
Atex Approve DN 25 Coriolis Mass Flowmeter for LNG Application
B. The  high-performance   32/40-bit  DSPs  are  used   as  the   core  processor,   including  high efficiency  instruction  set,  hardware  FFT  and  other peripherals  specially  used  for  audio  signal processing to fast process various digital signals in real time and largely improve the stability of flowmeters
 
C. The mass flowmeter is welded by the unique vacuum brass solder process, which ensures the welding quality and also fully guarantees the stress removal to largely improve the zero stability of mass flowmeter in use.
D. Water gauge calibration testing platform: The Company owns the scarce calibration systems and  stability  testing  system  for  water  gauges  with  large-span  diameter  (DN6-DN400)  in  the industry for the operating condition calibration and the stability testing of flowmeters.
E. High pressure gas testing platform: The Company has established the first high pressure air (25MPa)  calibration  system  and  stability  testing  system  in  China  for  the  operating  condition calibration and the stability testing of high-pressure flowmeters.
F. Liquid nitrogen low-temperature calibration testing platform: The Company has established the first copious cooling calibration system and stability testing system in China for the operating condition calibration and the stability testing of low-temperature flowmeters
 Atex Approve DN 25 Coriolis Mass Flowmeter for LNG Application

Atex Approve DN 25 Coriolis Mass Flowmeter for LNG ApplicationAtex Approve DN 25 Coriolis Mass Flowmeter for LNG ApplicationAtex Approve DN 25 Coriolis Mass Flowmeter for LNG ApplicationAtex Approve DN 25 Coriolis Mass Flowmeter for LNG ApplicationAtex Approve DN 25 Coriolis Mass Flowmeter for LNG ApplicationAtex Approve DN 25 Coriolis Mass Flowmeter for LNG Application



Atex Approve DN 25 Coriolis Mass Flowmeter for LNG Application
Atex Approve DN 25 Coriolis Mass Flowmeter for LNG Application
Atex Approve DN 25 Coriolis Mass Flowmeter for LNG Application
Atex Approve DN 25 Coriolis Mass Flowmeter for LNG Application


Atex Approve DN 25 Coriolis Mass Flowmeter for LNG Application
1. Customer: What is the delivery date?
Andisoon: Our stock is based on GB/DIN flange, with a delivery date of 10 days. We also accommodate other flanges like ANSI/JIS or thread connection, with a delivery date of 15 days.

2. Customer: Can you design according to my requirements?
Andisoon: Yes, we offer OEM service and can tailor products to your specifications.

3. Customer: What is the warranty period?
Andisoon: The quality guarantee period is 12 months from the completion of installation and commissioning by the purchaser, or 14 months from the date of delivery (whichever comes first), excluding maintenance kits or small accessories.






 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier